audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Connecting air conditioner service station on vehicles with no connection on the low-pressure end of the refrigerant circuit > < Connecting air conditioner service station
Connecting air conditioner service station on vehicles with a connection on the low and high-pressure end of the refrigerant circuit
Connecting air conditioner service station on vehicles with a connection on the low and high-pressure end of the refrigerant circuit
Connecting air conditioner service station for measuring and testing
–  Switch off ignition.
–  Connect air conditioner service station to power supply.
–  Connect quick-release coupling adapters to the charging hoses of the air conditioner service station (handwheels not screwed in/hand shut-off valve not open).
–  Switch on the air conditioner service station and evacuate the charging hoses (only necessary if there is air in the charging hoses).
–  Switch off air conditioner service station.
–  Unscrew sealing caps from service connections (with valve).
–  Connect up the air conditioner service station via the service connections with quick-release coupling adapters to the vehicle refrigerant circuit.
–  Only screw in the handwheel of the quick-release coupling adapters to the extent required to reliably open the valves at the refrigerant circuit connection (observe pressure gauge, do not open valves further than necessary).
–  Perform planned tests and measurements.
   

Connecting air conditioner service station on vehicles with no connection on the low-pressure end of the refrigerant circuit > < Connecting air conditioner service station