audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Combustibility > < Critical temperature/critical pressure
Water content
Water content
Only very small amounts of water are soluble in liquid refrigerant. In contrast, refrigerant vapour and water vapour mix in any ratio.
Any water in the refrigerant circuit will be entrained in droplet form once the dryer in the receiver or reservoir has absorbed as little as approx. 7 g of water. This water flows as far as the expansion valve nozzle or the restrictor and turns to ice. The air conditioner will then no longer provide any cooling effect.
Water causes irreparable damage to the air conditioner because at high pressures and temperatures it combines with other impurities to form acids.
   