audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Removing and installing reservoir with block connections > < Removing and installing refrigerant lines to the evaporator
Heating, Air Conditioner
Repairing refrigerant circuit - vehicles from Model Year 1997
Removing and installing refrigerant pipes on a condenser with block connection

Removing

  • ‒ Move lock carrier to service position.

=> General Body Assembly, Exterior; Repair group 50; Body front; Lock carrier service position

  • ‒ Drain the refrigerant circuit

=> Air conditioner - with refrigerant R134a

 
A87-0258
  • ‒ → Screw out the bolts -A- (20 Nm).
  • ‒ Remove the refrigerant pipes from the condenser.

Installing

Installation is carried out in the reverse order; note the following:

  • ‒ Replace the O-ring seals -B- (14.0 mm/1.8 mm) and -C- (10.8 mm/1.8 mm).

Removing and installing reservoir with block connections > < Removing and installing refrigerant lines to the evaporator