audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Encoding operating and display unit -E87 > < Basic setting
Heating, Air Conditioner
Erasing fault memory, ending output
Erasing fault memory, ending output

Prerequisite:

  • ● Fault memory interrogated.

Erase fault memory

 
→ Indicated on display
Rapid data transfer    HELP
Select function XX
  • ‒ Enter "05" for function "Erasing fault memory".
 
→ Indicated on display
Rapid data transfer    Q
05 - Erase fault memory
  • ‒ Confirm entry with Q key.
 
→ Indicated on display
Rapid data transfer    ⇒
Fault memory is erased
  • ‒ Press ⇒key.
 
→ Indicated on display:
Rapid data transfer    HELP
Select function XX

Notes:

 
→ Indicated on display
Important:
Fault memory has not been interrogated
  • ◆ Sequence has not been correctly followed.
  • ‒ Interrogate fault memory.
  • ‒ Rectify any faults.
  • ◆ Fault memory is not erased if, for example, ignition is switched off between interrogating and erasing fault memory.

End of output

Note:

The fault memory has been interrogated and erased, basic setting has been performed, and the encoding has been checked.

 
→ Indicated on display
Rapid data transfer    HELP
Select function XX
  • ‒ Press keys 0 and 6 for the function "End output".
 
→ Indicated on display
Rapid data transfer    Q
06 - End of output
  • ‒ Confirm entry with Q key.
 
→ Indicated on display
Rapid data transfer    HELP
Enter address word XX
  • ‒ Switch off ignition and detach diagnostic connector.

Encoding operating and display unit -E87 > < Basic setting