Notes for -E87 with Part No. 8D0 820 043 index "C":
During the self-diagnosis, the air conditioner control is switched off. When reading the different measured value blocks, note the following:
-
◆ All display zones marked with an * indicate the measured value valid on entering self-diagnosis mode.
-
◆ All display zones not marked with a * indicate the current measured value.
-
◆ If the displayed values are in display groups 002 - 005 (display zones 1and 2) are ambient the permitted tolerances:
-
‒ Terminate the self-diagnosis.
-
‒ If necessary, alter setting on the operating and display unit -E87.
-
‒ Run fresh-air blower at high speed for approx. 1 minute.
-
‒ Initiate self-diagnosis and read out measured value block.
Notes for -E87 with Part No. 8D0 820 043 from index "D" or Part No. 8L0 820 043 from index "A":
-
◆ During the self-diagnosis, the air conditioner control is kept on.
-
◆ The display groups 002 - 005 display the currently valid actual or specified value or the last value learnt and stored for the limit stops of the individual positioning motors during the basic setting.
-
◆ The control button on the -E87 may be pressed to change the setting of the positioning motors and hence the flaps during the self-diagnosis. The current actual and specified values may be read directly from the fault reader display.
-
◆ In Model Year 1996, in vehicles with 6-cylinder engines, compressors from the manufacturer "Nippondenso/Denso" are gradually replacing the former Zexel compressor. The air conditioner compressor speed sensor -G111 is omitted.
|