Heating, Air Conditioner
Reading measured value block
Reading measured value block

Note:

To check the speed signal after switching on the ignition, move the vehicle a few metres at walking speed.

Preconditions:

  • ● Fault memory interrogated .
  • ● Engine still idling after the interrogation of the fault memory
  • ● Air conditioner system switched on.
  • ● Run fresh-air blower for approx. 1 minute at a high speed (only operating and display unit with Part No. 8D0 820 043 index "C").
 
→ Indicated on display
Rapid data transfer    HELP
Select function XX
  • ‒ Press the PRINT key to switch on the printer - (indicator lamp in key lights up).
  • ‒ Enter "08" for the function "Reading measured value block" and confirm entry with Q key.
 
→ Indicated on display
Rapid data transfer    Q
08 - Read measured value block
  • ‒ Confirm entry with Q key.
 
→ Indicated on display
Reading measured value block    Q
Enter display group number XXX
  • ‒ Enter the display group number. =>Overview of display group numbers to be selected.
    • ‒ Vehicles to Model Year 1996 .
    • ‒ Vehicles from Model Year 1997 =>from Page 01-106.
 
→ Display readout:
Reading measured value block X    ⇒
    1    2    3    4

The measured value block shows 4 display zones:

Note:

To change to another display group, proceed as follows:

Display group

V.A.G 1551

V.A.G 1552

Higher

Press key 3

Press ↑ key

Lower

Press key 1

Press↓key

Skip

Press the C key

Press the C key

Notes:

  • ◆ If the printer is switched on, the current display will be recorded in the form of a printout.
  • ◆ If displayed values are to be read out while moving, a second operator is required.
  • ◆ Observe safety precautions=> Page 01-8.
  • ‒ Press ⇒key if specified values are attained.
 
→ Display function selection):
Rapid data transfer    HELP
Select function XX

Notes for -E87 with Part No. 8D0 820 043 index "C":

During the self-diagnosis, the air conditioner control is switched off. When reading the different measured value blocks, note the following:

  • ◆ All display zones marked with an * indicate the measured value valid on entering self-diagnosis mode.
  • ◆ All display zones not marked with a * indicate the current measured value.
  • ◆ If the displayed values are in display groups 002 - 005 (display zones 1and 2) are ambient the permitted tolerances:
    • ‒ Terminate the self-diagnosis.
    • ‒ If necessary, alter setting on the operating and display unit -E87.
    • ‒ Run fresh-air blower at high speed for approx. 1 minute.
    • ‒ Initiate self-diagnosis and read out measured value block.

Notes for -E87 with Part No. 8D0 820 043 from index "D" or Part No. 8L0 820 043 from index "A":

  • ◆ During the self-diagnosis, the air conditioner control is kept on.
  • ◆ The display groups 002 - 005 display the currently valid actual or specified value or the last value learnt and stored for the limit stops of the individual positioning motors during the basic setting.
  • ◆ The control button on the -E87 may be pressed to change the setting of the positioning motors and hence the flaps during the self-diagnosis. The current actual and specified values may be read directly from the fault reader display.
  • ◆ In Model Year 1996, in vehicles with 6-cylinder engines, compressors from the manufacturer "Nippondenso/Denso" are gradually replacing the former Zexel compressor. The air conditioner compressor speed sensor -G111 is omitted.