Note:
Valves must not be reworked. Only grinding-in (lapping) is permitted.
|
---|
Dimension
|
Inlet valve
|
Exhaust valve
|
a = ømm
|
26.8 ... 27.0
|
29.8 ... 30.0
|
b = ømm
|
5.96 ... 5.97
|
5.94 ... 5.95
|
c = mm
|
104.84 ... 105.34
|
103.64 ... 104.14
|
α = <°
|
45
|
45
|
Worn sodium-cooled exhaust valves must be treated as follows before disposal: Saw the valves into two sections with a metal saw at a point between the centre of the valve stem and the valve head. The valves must not come into contact with water when this is done. Then throw the valves into a bucket of water (not more than ten at a time) and step back, because a sudden chemical reaction occurs when the sodium filling burns. After this treatment the valves can be disposed of in the normal way.
|