audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Fault table > < Connecting fault reader V.A.G 1551 and selecting engine electronics control unit
Motronic Fuel Injection and ignition system (4-cyl.) 07.96ä
Self-diagnosis
Interrogating and erasing fault memory
  • ‒ Connect fault reader V.A.G 1551 (V.A.G 1552) and select the engine electronics control unit with the "Address word" 01. When doing this the engine must be running at idle speed
    (Connecting fault reader and selecting control unit for engine electronics .)

Only if engine does not start:

  • ‒ Interrogate fault memory with ignition switched on.
 
→ Indicated on display:
Rapid data transfer      HELP
Select function XX
  • ‒ Press keys 0 and 2 for "Interrogate fault memory" function and confirm entry with Q key.
 
→ The display shows the number of stored faults or "No fault recognised".
X faults detected

If no fault is stored:

  • ‒ Press the ⇒key.

If one or more faults are stored:

The stored faults are displayed and printed out one after another.
Then the display will show:

  • ‒ Locate and eliminate faults listed on printout as per fault table => Page 01-8.
  • ‒ Press keys 0 and 5 for the function "Erase fault memory" and confirm entry with Q key.
 
→ Indicated on display:
Rapid data transfer    ⇒
Fault memory is erased.

Note:

If the ignition is switched off between interrogating the fault memory and erasing the fault memory, then the fault memory will not be erased.

  • ‒ Press the ⇒key.
 
→ Indicated on display:
Rapid data transfer      HELP
Select function XX
  • ‒ Press keys 0 and 6 for the function "End output" and confirm entry with the Q key.

Fault table > < Connecting fault reader V.A.G 1551 and selecting engine electronics control unit