Technical data

Engine code letters

AGB (2.7 ltr. V6/5V / 195 kW biturbo engine / without secondary air inlet / satisfies emission standard Euro II-D3)

AZB (2.7 ltr. V6/5V / 195 kW biturbo engine / without secondary air inlet / satisfies emission standard Euro III) 2)

Idling speed
Not adjustable - controlled by the idling speed stabilisation

750...850 rpm

Engine speed limitation
by deactivation of injectors

approx. 6800 rpm

Fuel pressure at idling speed

Vacuum hose connected

approx. 3.5 bar

Vacuum hose disconnected

approx. 4 bar

Holding pressure after 10 minutes

at least 2.5 bar

Injectors

Spray pattern

Same for all injectors

Injection quantity (30s)

135...165 ml

Resistance (room temperature) 1)

13.5...15.5 ω

1)    When the engine is at operating temperature the resistance of the injectors is increased by approx. 4...6 ω.

2)    The "AZB" engine satisfies the EU III emission standard without secondary air inlet.