audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Readiness code > < Encoding control unit
Motronic Fuel Injection and Ignition System (6-cyl. Turbo)
Reading measured value block
Reading measured value block

Test conditions

  • ● Coolant temperature at least 80 °C
  • ● Electrical consumers switched off (radiator fan must not run during the check)
  • ● Air conditioner switched off
  • ‒ Connect the vehicle diagnostic, testing and information system VAS 5051 or fault reader V.A.G 1551 and select the engine electronics control unit with "address word" 01 .
    For this purpose, the engine must be running at idle speed.
 
→ Indicated on display:
Rapid data transfer     HELP
Select function XX
  • ‒ Press keys 0 and 8 for the function "Read measured value block" and confirm entry with Q key.
 
→ Indicated on display:
Read measured value block 08    
Enter display group number XXX
  • ‒ Enter relevant display group number (3 figures) and confirm entry by pressing Q.

Note:

The choice of display group depends on the particular functions and components to be tested.

 
→ Indicated on display (for example):
Read measured value block 0    ⇒
1    2    3    4    5    6    7    8    9    10

Note:

To change to another display group, proceed as follows:

Display group

V.A.G 1551

VAS 5051

Higher

Press key 3

Press s-key

Lower

Press key 1

Press tkey

Readiness code > < Encoding control unit