Engine code letters
|
ADP
|
Engine speed sender
|
Resistance approx. 450 ... 1000 ohm
|
Notes: ▪Ignition timing is determined by the control unit. ▪Ignition timing cannot be adjusted.
|
|
Basic setting of distributor* Display value on V.A.G. 1551 in function 04, "Basic setting, Display group 17, Display zone 3"
|
Test value 0 ± 12o
|
|
Setting: 0 ± 3o
|
Spark plugs (tightening torque 30 Nm)
|
Part no.101 000 033 AF101 000 051 AA
|
|
NGK BKUR 6 ETBOSCH F7 LTCR
|
Electrode gap
|
0.7 ... 0.9 mm0.9 ... 1.1 mm
|
Firing order
|
1-3-4-2
|
Spark plug connectors
|
4 ... 6 kohm
|
Suppresser
|
0.6 ... 1.4 kohm
|
Engine speed limitation by Motronic system Shut-off engine speed
|
6500 / min
|