Installing air mass meter -G70- |
To ensure the proper function of the air mass meter -G70- it is important to observe the following notes and instructions. |
Note t
| If the air filter element is very dirty or wet, dirt or water could reach the air mass meter -G70- and affect the air mass value. This would lead to loss of power, since a smaller injection quantity is calculated. |
t
| Always use genuine part for air filter element. |
t
| Use a silicone-free lubricant when installing the intake hose. |
t
| Secure all hose connections with the correct type of hose clips (same as original equipment): → Parts catalogue |
–
| Check for salt residue, dirt and leaves in air mass meter and air intake hose (engine intake side). |
–
| Check for dirt in air duct leading to air filter element. If necessary, clean salt residue, dirt and leaves out of air cleaner housing (top and bottom sections); wash out or use a vacuum cleaner as required. |
–
| If air cleaner element has been removed, blow out water drain in bottom section of air cleaner with compressed air. |
–
| If only the air mass meter (without housing) has been renewed separately, tighten bolts to specified torque. |
t
| Tightening torque: 4 Nm |
The remaining installation steps are carried out in the reverse sequence. |
|
|
|