| Watch linkage rod for intake manifold flap while a second mechanic switches off the engine. |
–
| When the engine is switched off, the intake manifold flap should close and remain closed for 1 or 2 seconds. |
Measure resistance if intake manifold flap does not close as described. |
Electrical check of intake manifold flap changeover valve -N239- |
–
| Unplug connector from intake manifold flap changeover valve -N239- ⇒ Fitting locations overview → Chapter. |
–
| Connect hand-held multimeter to measure resistance on intake manifold changeover valve -N239-. |
t
| Specification: 30...40 Ω |
If specification is not obtained: |
–
| Renew variable intake manifold flap changeover valve -N239-. |
If specification is obtained, check voltage supply. |
Checking voltage supply to intake manifold flap changeover valve -N239- |
|
|
|