ESP Electrical check
Electrical check; Test steps 1-12
Measuring resistance: Set measuring range (200 ω) on V.A.G 1526
|
Test step
|
V.A.G 1598/20 sockets
|
Testing of
|
▪ Test conditions - Additional operations
|
Specified value
|
Action in the event of deviation from specified value
|
1
|
5 + 3
|
Inlet valve -N101, outlet valve -N102, front left
|
|
|
- Infinite resistance indicates an open circuit in wiring. Check accordingly.
|
2
|
55 + 26
|
Inlet valve -N99, outlet valve -N100, front right
|
|
9ω/22ω
|
- A resistance reading below the specified range indicates a short between the two wires. Check accordingly.
|
3
|
53 + 25
|
Inlet valve -N134, outlet valve -N136, rear left
|
|
|
- In all cases test wiring for short to earth and short to positive.
|
|
---|
Measuring resistance: Set measuring range (200 ω) on V.A.G 1526
|
Test step
|
V.A.G 1598/20 sockets
|
Testing of
|
▪ Test conditions - Additional operations
|
Specified value
|
Action in the event of deviation from specified value
|
4
|
6 + 4
|
Inlet valve -N133, outlet valve -N135, rear right
|
|
9ω/22ω
|
=> Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder If electrical wiring is OK renew hydraulic unit.
|
5
|
49 + 50
|
- Switch valve 1 for ESP -N225
|
|
|
- Infinite resistance indicates an open circuit in wiring. Check accordingly.
|
|
|
- Switch valve 2 for ESP -N226
|
|
12ω/28ω
|
- A resistance reading below the specified range indicates a short between the two wires. Check accordingly.
|
|
---|
Measuring resistance: Set measuring range (200 ω) on V.A.G 1526
|
Test step
|
V.A.G 1598/20 sockets
|
Testing of
|
▪ Test conditions - Additional operations
|
Specified value
|
Action in the event of deviation from specified value
|
6
|
52 + 54
|
- High-pressure switch valve 1 for ESP -N227
|
|
6ω/16ω
|
- In all cases test wiring for short to earth and short to positive.
|
|
|
- High-pressure switch valve 2 for ESP -N228
|
|
|
=> Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder If electrical wiring is OK renew hydraulic unit.
|
7
|
8 + 10 1) 9 + 10 2)
|
Speed sensor -G47, front left
|
|
400ω/2300ω
|
- Infinite resistance indicates an open circuit in wiring. Check accordingly.
|
The output connections on control unit -J104 are wired differently for the various different versions.
1) 4WD vehicles
2) FWD vehicles
Measuring resistance: Select measuring range on V.A.G 1526 (2 kω or 20 kω)
|
Test step
|
V.A.G 1598/20 sockets
|
Testing of
|
▪ Test conditions - Additional operations
|
Specified value
|
Action in the event of deviation from specified value
|
8
|
15 + 16
|
Speed sensor -G45, front right
|
|
|
- A resistance reading below the specified range indicates a short between the two wires. Check accordingly.
|
9
|
13 + 14
|
Speed sensor -G46, rear left
|
|
400ω/2300ω
|
- In all cases test wiring for short to earth and short to positive.
|
10
|
11 + 12
|
Speed sensor -G44 rear right
|
|
|
=> Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder If the electrical wiring is OK renew the relevant speed sensor.
|
Measuring resistance: Select measuring range on V.A.G 1526 (200 ω)
|
Test step
|
V.A.G 1598/20 sockets
|
Testing of
|
▪ Test conditions - Additional operations
|
Specified value
|
Action in the event of deviation from specified value
|
11
|
2 + 37 1) 2 + 36 2)
|
Actuation of solenoid valve relay -J106
|
|
|
- Infinite resistance indicates an open circuit in wiring. A resistance reading below the specified range indicates a short between the two wires.
|
12
|
2 + 7
|
Actuation of return pump relay -J105
|
|
5font=symbol charset=fontspecific code=48 descr='[nd0]'ω/70ω
|
- In all cases test wiring for short to earth and short to positive. => Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder Replace relay if wiring is OK and specified value is not attained.
|
The output connections on control unit -J104 are wired differently for the various different versions.
1) Vehicles with control unit 4B0 907 389
2)Vehicles with control unit 8D0 907 389/A/D/E
|