audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Reading measured value block > < End of output
Encoding control unit
Encoding control unit
  Note
Encoding sets the dash panel insert to the specific vehicle equipment.
   
Sequence of operations
–  Start dash panel insert self-diagnosis → Chapter.
Display on -VAS 5051B-:
–  From list -1-, select function “07 - Encoding control unit”.
  A01-0122
Display on -VAS 5051B-:
1 - Enter code word
  A01-0130
Encoding table
Optional extras0   No optional extras
 1   Brake lining wear indicator active
 2   Seat belt warning system active
 4   Washer fluid warning system active
 16   Navigation system
If the vehicle is fitted with several encodable optional extras, add up the numbers of the individual optional extra codes. Example:
l  Brake lining wear indicator active, washer fluid warning system active: 1 + 4 = 5.
Country version 0  Germany (D)
  1  Europe (EU)
  2  USA (USA)
  3  Canada (CDN)
  4  Great Britain (GB)
  5  Japan (J)
  6  Saudi Arabia (SA)
  7  Australia (AUS)
Number of cylinders  4 4-cylinder
   6 6-cylinder
Engine version   0TDI engine
    2Petrol engine

   
Display on -VAS 5051B-:
–  Use keypad -2- to enter the control unit code as per encoding table.
  A01-0130
Example:
5040← Keypad entry (max. 5-digit)
    TDI engine: 0
    4-cylinder: 4
    Germany (D): 0
    Brake lining wear indicator active, washer fluid warning system active: 1 + 4 = 5

–  Confirm entry by touching Q key.
Display on -VAS 5051B-:
1 - Encoding in progress
–  Wait until next display appears.
   
Display on -VAS 5051B-:
1 - Vehicle system encoding completed
2 - Control unit identification with new code (old code in parentheses)
–  Terminate function “07 - Encoding control unit” by touching  key.
  A01-0136
Fault messages on -VAS 5051B-
If display zone -1- shows the fault message “Function unknown or cannot be implemented at present”:
–  Check whether the correct dash panel insert has been fitted → Parts catalogue. Or a non-released code has been entered. Repeat the encoding procedure if necessary.
  A87-0314

Reading measured value block > < End of output