Interrogating fault memory |
Note t
| The operating and display unit, Climatronic control unit -J255- switches automatically to “Econ” mode if, following installation of a new operating and display unit, Climatronic control unit -J255-, basic setting was not performed or if the pressure measured by the high-pressure sender -G65- is too low or too high (the compressor must not be activated) → Chapter. This status is displayed as being a fault as of hardware/software version “0711”. |
t
| If, after switching on the ignition, the operating and display unit, Climatronic control unit -J255- switches automatically to “Off” mode and if it is only possible to set “Def” mode with the ignition switched on (no other settings possible), the ignition has been switched on for example using a key not released for the vehicle concerned or the control unit in dash panel insert -J285- is not transmitting a key number by way of the convenience data bus system (provided as of hardware/software version “0711”). |
t
| If the operating and display unit, Climatronic control unit -J255- displays a number, interrogate the fault memory of the operating and display unit, Climatronic control unit -J255- (the number “60” for example indicates a fault at the temperature sensor blower -V42-). If the display of the operating and display unit, Climatronic control unit -J255- flashes and no fault is displayed in the fault memory (e.g. with display “09”), there is a fault in the electronics of the operating and display unit, Climatronic control unit -J255-. |
|
|
|