audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Checking hydraulic bucket tappets > < Removing and installing camshafts and camshaft adjuster
Renewing valve stem oil seals
   
Renewing valve stem oil seals
Special tools and workshop equipment required
t  Pressure hose -VW 653/3-
t  Spark plug socket and extension -3122 B-
t  Valve stem seal puller -3364-
t  Valve stem seal fitting tool -3365-
t  Removal and installation device for valve cotters -VAS 5161-

Procedure
–  Remove camshafts and camshaft adjuster → Chapter.
  Note
t  Take care not to interchange bucket tappets.
t  Use waterproof felt-tip pen to mark assignment of bucket tappets on back of tappets.
–  Take bucket tappets out of guides and set them down with contact surface facing downwards.
–  Remove spark plugs with spark plug socket -3122 B-.
–  Set piston of the respective cylinder to „bottom dead centre“.
   
–  Screw pressure hose -VW 653/3- into spark plug hole and connect to compressed air supply.
l  Minimum pressure: 6 bar.
–  Insert punch -VAS 5161/3- in bucket tappet guide.
–  Knock valve cotters on all five valves loose using a plastic hammer.
  A15-0556
Exhaust side:
–  Screw snap-in device -VAS 5161/6- with interlocking fork -VAS 5161/4- onto stud on cylinder head.
–  Push guide bush -VAS 5161/14- as far as it will go into bucket tappet guide for valve to be removed.
l  Installation position: knurled surfaces face perpendicular to direction of travel.
–  Slide knurled spacer ring -VAS 5161/17- onto assembly cartridge -VAS 5161/8-.
–  Insert assembly cartridge into guide bush.
–  Attach pressure fork -VAS 5161/2- to snap-in device -VAS 5161/6- and push assembly cartridge down.
–  At the same time, turn knurled screw of assembly cartridge clockwise until tips engage in valve cotters.
–  Move knurled screw back and forth slightly; the valve cotters are thus forced apart and taken up by the cartridge.
–  Release pressure fork.
–  Take out assembly cartridge with spacer ring, guide bush, valve spring plate and valve spring.
  A15-0557
Inlet side
–  Screw snap-in device -VAS 5161/6- with interlocking fork -VAS 5161/4- onto stud on cylinder head.
–  Push guide bush -VAS 5161/13- as far as it will go into bucket tappet guide for valve to be removed.
t  Installation position: knurled surfaces face perpendicular to direction of travel.
–  Slide knurled spacer ring -VAS 5161/17- onto assembly cartridge -VAS 5161/8-.
–  Insert assembly cartridge into guide bush.
–  Attach pressure fork -VAS 5161/2- to snap-in device -VAS 5161/6- and push assembly cartridge down.
–  At the same time, turn knurled screw of assembly cartridge clockwise until tips engage in valve cotters.
–  Move knurled screw back and forth slightly; the valve cotters are thus forced apart and taken up by the cartridge.
–  Release pressure fork.
–  Take out assembly cartridge with spacer ring, guide bush, valve spring plate and valve spring.
  A15-0558
Continuation for both sides:
–  Remove valve stem oil seals using the valve stem seal puller -3364-.
  Note
  A15-0559
A plastic sleeve -A- is included with the new valve stem oil seals.
–  Fit plastic sleeve -A- onto the valve stem to prevent damage to the new valve stem oil seal -B-.
–  Lightly lubricate sealing lip of valve stem oil seal.
–  Slip valve stem oil seal over plastic sleeve.
–  Carefully press valve stem oil seal onto valve guide using valve stem seal fitting tool -3365-.
–  Remove plastic sleeve.
  A15-0282
–  If valve cotters have been removed from assembly cartridge, they need to be put into insertion device -VAS 5161/18- first.
l  Larger diameter of valve cotters faces upwards.
–  Press assembly cartridge -VAS 5161/8- onto insertion device from above and pick up valve cotters.
  A15-0445
–  Re-insert cartridge into guide bush -VAS 5161/13- or -VAS 5161/14-.
–  Push pressure fork down and pull knurled screw upwards while turning to left and right - this will insert the valve cotters.
–  Release pressure fork with knurled screw still in pulled position.
–  Insert bucket tappets.
–  Install camshafts and camshaft adjuster → Chapter.
  Note
t  After installing camshafts, wait for approx. 30 minutes before starting engine. Hydraulic valve compensation elements have to settle (otherwise valves will strike pistons).
t  After working on the valve gear, turn the engine carefully at least 2 rotations to ensure that none of the valves make contact when the starter is operated.
  A15-0557

Checking hydraulic bucket tappets > < Removing and installing camshafts and camshaft adjuster