audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Removing and installing exhaust gas recirculation cooler > < Exhaust gas recirculation system
Exhaust gas recirculation system - exploded view
   
Exhaust gas recirculation system - exploded view
1 - Gasket
q   Renew
2 - 25 Nm
3 - Connecting pipe for exhaust gas recirculation
q   Tightening sequence
4 - Coolant hoses
5 - Exhaust gas recirculation cooler
q   Removing and installing → Chapter
6 - Bracket
7 - Retaining pin for engine cover panel
8 - 9 Nm
9 - Gasket
10 - Vacuum unit
11 - Vacuum hose
q   From exhaust gas recirculation cooler change-over valve -N345-
12 - 7 Nm
13 - 9 Nm
14 - Gasket
q   Renew
15 - 25 Nm
q   Renew

   
Tightening sequence: connecting pipe for exhaust gas recirculation
  Note
The connecting pipe for exhaust gas recirculation must be installed free of stress as described below:
1.  Tighten bolt connections -1 … 6- for connecting pipe for exhaust gas recirculation hand-tight.
2.  Tighten bolt connections for connecting pipe for exhaust gas recirculation to specified torque in the sequence -1 … 6-.
  A26-10496

Removing and installing exhaust gas recirculation cooler > < Exhaust gas recirculation system