Hand-operated vacuum pump -VAS 6213- or hand-operated vacuum pump with attachments -V.A.G 1390-
t
Water drain container -V.A.G 1390/1-
Draining
–
Unscrew bleeder screw -2- at fuel filter completely.
–
Connect hand-operated vacuum pump -VAS 6213- (or hand-operated vacuum pump -V.A.G 1390-) together with water drain container -V.A.G 1390/1- to bleeder connection at fuel filter.
–
Operate hand pump until approx. 100 cm3 of fluid is drawn out of fuel filter.
WARNING
No fluid must be allowed to enter the hand-operated vacuum pump.
–
Start engine and inspect fuel system for leaks (visual check).