Discharging refrigerant circuit with air conditioner service station > < Important notes for working with the air conditioner service station
Connecting air conditioner service station for measuring and testing
Connecting air conditioner service station for measuring and testing
l  Work procedure may vary depending on the type of tools selected; therefore it is important to observe the tool-specific operating instructions.
  Note
The work procedure must always be performed as described in the operating instructions of the air conditioner service station.
To prevent air or moisture entering the refrigerant circuit through the charging hoses, these are to be connected as follows:
–  Switch off ignition.
–  Connect air conditioner service station to power supply.
–  Unscrew the sealing caps from the service connections or the connections with valve (refer to vehicle-specific refrigerant circuit) → Heating, air conditioning; Rep. gr.87 or → Air conditioning; Rep. gr.87 (vehicle-specific workshop manual).
–  Evacuate the charging hoses if necessary.
–  Connect quick-release coupling to service connection of refrigerant circuit.
  WARNING
Do not open the valves on the low or high-pressure end with the engine running, as otherwise the air conditioner compressor or the air conditioner service station could be destroyed by a short circuit between the high and low-pressure ends of the refrigerant circuit if the air conditioning system is switched on.
–  Only screw the handwheel into the quick-release coupling adapter to the extent required to reliably open the valve in the service connection (observe the pressure gauge; take care not to open the valve too far).
–  Start the engine and perform the intended tests and measurements.
–  Compare the values determined to the specified measured values → Chapter.
–  Before detaching the quick-release coupling, close it by screwing out the handwheel.
Vehicles with one service connection only:
  Note
Screw the valve adapters -V.A.G 1785/9-, -V.A.G 1785/10- or the adapter set -V.A.G 1786- to the refrigerant circuit connections with valve and bleed the charging hoses during connection to the adapters (only a faintly audible escape of refrigerant gas is permitted) → Chapter.
–  The charging hose must be fitted with a valve opener to open the valve in the valve adapter.
   

Discharging refrigerant circuit with air conditioner service station > < Important notes for working with the air conditioner service station