| Wipe over the bonding surface -D- at the operating and display unit -A- e.g. using cleaning fluid D 009 401 04 → Electronic parts catalogue. |
–
| Install the operating and display unit -A-. |
Note t
| If the trim panel -B- is to be re-used on replacing the operating and display unit, Climatronic control unit -J255--A-, remove the adhesive tape -C- from the trim panel -B-. Clean the bonding surface at the trim panel -B- as described in the usage and handling instructions for the adhesive tape. Then stick a strip of double-sided adhesive tape -C- (dimensions: 204 mm x 10 mm, thickness approx. 1.2 mm; e.g. adhesive tape D 438 515 A1 → Electronic parts catalogue) onto the trim panel -B-. |
–
| Position the trim panel -B- with the adhesive tape -C- on the bonding surface -D- of the operating and display unit -A- and align the trim panel -B-. |
–
| Press the trim panel -B- onto the bonding surface -D-. |
–
| Re-encode (or check the encoding of) the air conditioner operating and display unit, Climatronic control unit -J255-. |
–
| Perform basic setting of the air conditioner operating and display unit, Climatronic control unit -J255-. |
–
| Interrogate the event recorder of the air conditioner operating and display unit, Climatronic control unit -J255- (eliminate the cause of any faults displayed) and erase the event recorder. |
–
| Check and if necessary correct the adaption of the air conditioner operating and display unit, Climatronic control unit -J255-. |
–
| Perform final control diagnosis for the air conditioner operating and display unit, Climatronic control unit -J255- (depending on the problem concerned). |
|
|
|