Central gas venting system
Central gas venting system
To prevent the gas produced when charging the battery from causing damage or becoming a health hazard, the gas is discharged through a central opening in the top of the battery cover.
–  Make sure that the central gas venting system hose or pipe is always attached to the battery.
–  Make sure the central gas venting system hose or pipe is not obstructed. Only then is the battery able to vent freely.
  Note
More modern batteries are equipped with a fine-mesh flame trap at the central gas venting outlet. This circular glass-fibre mesh with a diameter of approx. 15 mm and a thickness of 2 mm operates like a valve. It allows the gas given off during battery charging to escape and at the same time prevents ignition of the explosive gas in the battery.
   