Online calibration > < When is it necessary to calibrate the system?
Calibration procedure
Calibration procedure
For details of the exact calibration procedure, refer to the Workshop Manual. The main calibration steps are described below:
t  The "lane departure warning calibration" program is started on the wheel alignment computer.
t  Quick release clamps are mounted on all 4 wheels.
t  Wheel alignment sensors are mounted on the two rear wheels.
t  Wheel runout compensation is performed on the rear wheels.
t  Two wheel alignment sensors are attached to the VAS 6430.
t  The setting device VAS 6430 is aligned with the direction of travel in several steps using the wheel alignment computer as a guide.
t  The calibration program on the diagnostic tester is started under "Guided Fault Finding".
t  The body height is measured at the edges of all four wheel arches and entered into the program.
t  The calibration routine then runs to completion automatically.
   

Online calibration > < When is it necessary to calibrate the system?