A4 Quattro Cabriolet L4-2.0L Turbo (BWT) (2009)
-
Open cable ties on the wiring harness on the coolant pipe.
-
Remove bracket - arrows - from coolant pipe.
-
Carefully pry off linkage from Intake Flap Motor (V157) - 4 -.
-
Disconnect all necessary electrical connectors and press coolant pipe far enough to the side so the intake flap motor (V157 ) bolts can be accessed.
-
Remove Intake Flap Motor (V157) - 5 -.