Oxygen Sensor: Testing and Inspection
Oxygen Sensor 1 Heater After Catalytic Converter, Checking

Oxygen Sensor 1 Heater after Catalytic Converter, Checking

‹› Oxygen Sensor (O2S) 1 (behind Three Way Catalytic Converter (TWC)) Heater ( Z29) is part of Oxygen Sensor (O2S) Behind Three Way

Catalytic Converter (TWC) ( G130) and cannot be replaced separately.

‹› When servicing terminals in harness connector of Oxygen Sensor (O2S) Behind Three Way Catalytic Converter (TWC) ( G130), use only

gold-plated terminals.

Special tools, testers and auxiliary items required

‹› Multimeter.

‹› Wiring diagram.

Test requirements

‹› Fuse (S344) OK.

‹› Engine Component Power Supply Relay (J757) OK. 

‹› Battery voltage at least 12.5 volts.

‹› All electrical consumers such as, lights and rear window defroster, switched off.

‹› Vehicles with automatic transmission, shift selector lever into position " P" or "N".

‹› A/C switched off.

‹› Ground (GND) connections between engine/transmission/chassis OK.

‹› Ignition switched off.

Test procedure

-

Perform a preliminary check to verify the customers complaint. Refer to => [ General Diagnosis ] See: Testing and Inspection/Initial Inspection
and Diagnostic Overview/General Diagnosis.

Start diagnosis

-

Disconnect the electrical harness connector - 2 - from the Oxygen Sensor (O2S) Behind Three Way Catalytic Converter (TWC) ( G130).

Checking internal resistance

-

Using the Multimeter (V.A.G 1526 A) or equivalent, check the Oxygen Sensor (O2S) Behind Three Way Catalytic Converter (TWC) (G130)

Oxygen Sensor Heater, Checking|Page 3465 > < Oxygen Sensor Heater, Checking|Page 3463