audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Turbocharger Recirculating Valve, Checking|Page 3937 > < Turbocharger Recirculating Valve, Checking|Page 3935
Page 3
background image

-

Operate the starter briefly.

Specified value: battery voltage.

-

Switch the ignition off.

If the specified value was not obtained:

-

Check the Wastegate Bypass Regulator Valve (N75 ) electrical harness connector terminal 1 to the Engine Component Power Supply Relay (J757)
socket 2/87 for an open circuit, short circuit to each other, Battery (+), or Ground (GND).

-

Check the electrical harness connector for damage, corrosion, loose or broken terminals.

-

If necessary, repair the wiring connection. 

If no malfunctions are found in the wiring:

Checking wiring

If the manufacturers test box is being used. Perform the following step.

-

Install the test box. Refer to Fuel Injection and Ignition Repair Information

If the manufacturers test box is not being used. Perform the following step.

-

Remove the Engine Control Module (ECM) (J623). Refer to => [ Engine Control Module, Replacing ] See: Computers and Control
Systems/Engine Control Module/Service and Repair.

-

Using a multimeter, check the Wastegate Bypass Regulator Valve (N75) electrical harness connector terminal 2 to Engine Control Module (ECM)
(J623) electrical harness connector T60 terminal 21 for resistance.

Turbocharger Recirculating Valve, Checking|Page 3937 > < Turbocharger Recirculating Valve, Checking|Page 3935