audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Main Relay (Computer/Fuel System) > < Fuel Pump Relay|Testing and Inspection|Page 3910
Page 4
background image

-

Disconnect fuses S228, S229 and S234 (positions 28, 32 and 34) in fuse holder.

-

Initiate final control diagnosis and actuate evaporative emission (EVAP) canister purge regulator valve - N80-.

-

To measure voltage, connect multimeter to Ground and to one terminal of following fuses in fuse holder.

Fuse

Specified value at one of the terminals

S228

approx. battery voltage

S232

approx. battery voltage

S234

approx. battery voltage

If the specified values are not obtained:

-

Repeat test at other terminal of fuse base.

If the specifications are still not obtained:

-

Check wiring connections.

If no DTC is found:

-

Replace fuel pump (FP) relay -J17-.

-

Reinsert fuses

Main Relay (Computer/Fuel System) > < Fuel Pump Relay|Testing and Inspection|Page 3910