Operate starter briefly.
-

LED should illuminate.

If the LED does not illuminate:

-

Check wiring from terminal 1 on connector via fuse to fuel pump relay for an open circuit.

-

Repair open circuit if necessary.

If LED lights up:

Checking actuation

-

Connect voltage tester VAG1527 B between terminals 1 and 2.

-

Initiate final control diagnosis and activate intake manifold change-over valve.
-

LED should flash.

If the LED lamp does not flash or if it illuminates continuously:

-

Connect test box VAG1598/31 to wiring harness for engine control module; engine control module must not be connected.

-

Check for open circuit and short to positive or Ground in following wiring connections:

Connector

Test box VAG1598/31

terminal

Socket

2

48

-

Repair any open/short circuit as necessary.

If no wiring malfunction is detected:

-

Replace engine control module.