audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Batteries With Central Gas Venting|Page 5830 > < Technician Safety Information
Page 1
background image

Battery: Vehicle Damage Warnings
Batteries With Central Gas Venting

Batteries with central gas venting

WARNING:

-

New style batteries with central gas venting must be installed.

-

Always use original battery sealing plugs. The plugs must be installed with an O-ring seal.

There are two types of batteries with a central gas venting:

-

Batteries with a hose or connection for central gas venting

-

Batteries without a hose or connection for central gas venting

NOTE:
-

The latest generation of batteries are equipped with a central gas venting system and a fine mesh flame trap. Function:
Gas produced during charging escape through a central opening on the top part of the battery cover. The flame trap which prevents flammable
gases in the battery from igniting is also located at this point..The flame trap consists of a small round fiberglass mat about 15 mm in diameter
and 2 mm thick. It works similarly to a valve, i.e. it allows gas produced in the battery to vent.

-

Do not grease battery terminals.

-

To avoid damaging the battery housing, put the battery clamps on only by hand, without forcing them.

Notes on operation of central gas venting system:

-

For batteries with hose/line for central gas venting system, make sure the hose is not kinked, otherwise the battery will not be properly vented.

-

0n batteries with no central gas venting hose/line, it is important to ensure that opening in top cover -arrow- is not clogged.

Checking battery for secure seating

If battery is not securely seated, the following dangers exist:

-

Shortened service life caused by vibration damage.

-

The cells in battery will be damaged if battery is not secured correctly.

-

Damage to battery housing by clamping bracket (possible acid leakage, high subsequent costs).

-

Poor crash safety.

-

Make sure that battery does not leak, only install genuine battery caps.

-

Use genuine sealing plugs of same construction if lost or damaged.

-

The sealing plugs must be provided with an O-ring.