Refrigerant Lines For Condenser, Removing and Installing
Refrigerant Lines For Condenser, Removing And Installing
Disconnecting
-
Discharge refrigerant circuit
-
Remove noise insulation
-
Remove entire front bumper
-
Remove bolts - A - (tightening torque 20 Nm).
-
Remove refrigerant lines from condenser.
NOTE: Seal open lines and connections at condenser with suitable caps (to prevent dirt and moisture).
Installing
Install in reverse order, paying attention to the following:
-
After attaching, check routing of refrigerant lines - A -. They must be inserted in brackets - B - provided and not make contact with other
components.
-
Replace O-rings - B - and - C - .
-
Check type of seal at connections and refrigerant lines (must be designed for same type of seal).
-
Evacuate and recharge refrigerant circuit.