Canister Purge Control Valve|Testing and Inspection|Page 4645 > < Canister Purge Control Valve|Testing and Inspection|Page 4643
Page 4
background image

If the manufacturers test box is being used. Perform the following step.

-

Install the test box. Refer to Fuel Injection and Ignition Repair Information.

If the manufacturers test box is not being used. Perform the following step.

-

Remove the Engine Control Module (ECM) (J623 ). Refer to => [ ECM, Removing and Installing ] See: Computers and Control Systems/Engine
Control Module/Service and Repair/ECM, Removing and Installing.

-

Using a Multimeter, check the Evaporative Emission (EVAP) Canister Purge Regulator Valve (N80) electrical connector terminal 2 to Engine
Control Module (ECM) (J623 ) electrical connector T94 terminal 49 for an open circuit.

Specified value: 1.5 ohms max.

If the specification is not obtained:

-

Check the wiring for a short circuit to Battery positive (+), Ground (GND) or an open circuit.

-

Check the electrical harness connector for damage, corrosion, lose or broken terminals.

-

If necessary, repair the wiring connection.

If the specification was obtained:

-

Replace the Engine Control Module (ECM) (J623 ). Refer to => [ ECM, Removing and Installing ] See: Computers and Control Systems/Engine
Control Module/Service and Repair/ECM, Removing and Installing.

-

Install the rear engine cover - arrows -.