Oxygen Sensor: Testing and Inspection
Oxygen Sensors After Catalytic Converter, Checking

Oxygen Sensors after Catalytic Converter, Checking

This procedure is used to diagnose Oxygen Sensor (O2S) Behind Three Way Catalytic Converter (TWC) (G130) or Oxygen Sensor (O2S) 2 Behind
Three Way Catalytic Converter (TWC) ( G131).

‹› When servicing the electrical harness connector of the Oxygen Sensors (O2S) Behind Three Way Catalytic Converter (TWC), use only

gold-plated terminals.

Special tools, testers and auxiliary items required

‹› Multimeter.

‹› Wiring diagram.

Test requirements

‹›  The Oxygen Sensor (O2S) Behind Three Way Catalytic Converter (TWC) (G130) fuse OK.

‹› The Oxygen Sensor (O2S) 2 Behind Three Way Catalytic Converter (TWC) (G131) fuse OK. Refer to => [ Oxygen Sensor Heater after Catalytic

Converter, Checking ] See: Testing and Inspection/Component Tests and General Diagnostics/Component Tests (VAG Code Tests)/Oxygen
Sensor Heater After Catalytic Converter, Checking. 

‹› Battery voltage at least 12.5 volts.

‹› All electrical consumers such as, lights and rear window defroster, switched off.

‹› Vehicles with automatic transmission, selector lever in position " P" or "N".

‹› A/C switched off.

‹› Ground (GND) connections between engine/transmission/chassis OK.

‹› Exhaust system between catalytic converter and cylinder head properly sealed.

‹› Coolant Temperature at least 80° C.

Function test

Perform a function test of the Heated Oxygen Sensors (HO2S). Refer to ADD LINK

If specified values are obtained:

-

End diagnosis and switch the ignition off.

If the specified values are not obtained:

Test procedure

-

Perform a preliminary check to verify the customers complaint. Refer to => [ General Diagnosis ] See: Testing and Inspection/Initial Inspection
and Diagnostic Overview/General Diagnosis.

Start diagnosis

-

Disconnect the Oxygen Sensor (O2S) Behind Three Way Catalytic Converter (TWC) (G130) electrical harness connector -  2 -.

Oxygen Sensor Heaters Before Catalytic Converter, Checking|Page 3688 > < Oxygen Sensor Heaters Before Catalytic Converter, Checking|Page 3686