Using a Multimeter, check the Oxygen Sensor (O2S) 2 Behind Three Way Catalytic Converter (TWC) electrical harness connector terminals 3 to
4 for voltage.

-

Switch the ignition on. 

Specified value: 0.400 to 0.500 V. 

-

Switch the ignition off.

If the specified value was obtained:

-

Replace the faulty Oxygen Sensor (O2S) Behind Three Way Catalytic Converter (TWC). Refer to Fuel Injection and Ignition Repair Information.

If the specified value was not obtained:

Checking wiring

If the manufacturers test box is being used. Perform the following step.

-

Install the test box. Refer to Fuel Injection and Ignition Repair Information.

If the manufacturers test box is not being used. Perform the following step.

-

Remove the Engine Control Module (ECM) (J623 ). Refer to => [ ECM, Removing and Installing ] See: Engine Control Module/Service and
Repair/ECM, Removing and Installing.

-

Using a Multimeter, check the Oxygen Sensor (O2S) Behind Three Way Catalytic Converter (TWC) electrical harness connector terminals to the
Engine Control Module (ECM) (J623) electrical harness connector T94 terminals for an open circuit.