audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Oxygen Sensor Heaters Before Catalytic Converter, Checking|Page 3693 > < Oxygen Sensor Heaters Before Catalytic Converter, Checking|Page 3691
Page 2
background image

-

Disconnect the Engine Coolant Level (ECL) Warning Switch (F66) electrical connector from the bottom of the coolant reservoir and set aside the
coolant reservoir with the coolant hoses -  1 - and - 2 - connected.

-

Disconnect the Oxygen Sensor (O2S) Heater (Z30 ) electrical harness connector - 1 -.

Checking internal resistance

-

Using a multimeter, check the Oxygen Sensor (O2S) Heater terminals 1 to 2 for resistance.

Specified value: 1.0 to 20.0 ohms (at approx. 20° C)