Disconnect the Engine Coolant Level (ECL) Warning Switch (F66) electrical connector from the bottom of the coolant reservoir and set aside the
coolant reservoir with the coolant hoses -  1 - and - 2 - connected.

-

Disconnect the Oxygen Sensor (O2S) Heater (-Z28- ) electrical harness connector - 2 -.

Checking internal resistance

-

Using a multimeter, check the Heated Oxygen Sensor (HO2S) terminals 3 to 5 for resistance.

Specified value: 2.5 to 10.0 ohms (at approx. 20° C)