Battery: Description and Operation
Battery, Charging

Battery

The battery is one of the most important electrical components in the vehicle. Its proper functioning is a major factor in ensuring customer satisfaction.
To guarantee a long service life, the battery must be checked, serviced and maintained as described in this service information.

In addition to its function of starting the vehicle, the battery performs other tasks as a buffer and a source of electrical energy for the vehicle's entire
electrical system.

Battery, Charging

Special tools, testers and auxiliary items required

‹› Battery charger

The battery should be charged using a battery charger (VAG), for example (VAG 1471), (VAG 1648) or (VAS 1974).

CAUTION!
The battery plugs must be fully tightened when charging, measuring voltage or performing load tests.

Rooms in which batteries are charged must not be entered with a open flame or while smoking. As the battery forms gas which is readily
flammable during the charging process.

‹› The battery temperature must be at least 10 °C.

‹› Batteries should only be fast charged (e. g. boost starting) in exceptional circumstances; as fast charging causes damage.

‹› If fast charging is performed on heavily discharged batteries, they fail to absorb any charging current or register as being fully charged prematurely

due to so-called surface charging. They appear to be OK.

Procedure

See Caution before beginning repairs on the electrical system => [ Battery ] See: Service and Repair/Removal and Replacement/Battery

-

Switch off battery charger.

-

Note and if necessary, determine radio code for vehicles equipped with coded anti-theft radio / radio navigation system only foreign brands). 

-

Switch ignition off.

-

Push cover over battery to the right - arrow 1 - and remove by lifting off - arrow 2 -.

-

Disconnect Ground strap - 1 - on battery negative terminal and detach positive cable - 2 - on battery positive terminal.