audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Safety Precautions|Page 7504 > < Safety Precautions|Page 7502
Page 2
background image

-

Connect positive lead of battery charger to positive terminal of battery.

-

Connect negative lead of battery charger to negative terminal of battery.

-

Adjust charge current at battery charger according to battery capacity. It should amount to approx. 10% of the battery capacity. For a 60 Ah
battery, approx. 6 A.

-

Switch on battery charger.

Installation is reverse of removal, paying attention to the following: 

-

Connect battery. Required steps. 

Notes on heavily discharged batteries:

Batteries which have not been used in driving operation for a long time, for example in stored vehicles, discharge themselves.

A battery is heavily discharged, if the no-load voltage has dropped below 11.6 V. Measuring no-load voltage => [ Battery, Checking No Load Voltage

In severely discharged batteries the electrolyte (a mixture of sulfuric acid and water) consists almost entirely of water, since the proportion of sulfuric
acid is strongly reduced. At minus temperatures, the battery can freeze and the housing can crack.

Heavily discharged batteries become sulfated, i.e. all the plate surfaces of such batteries become hard. The electrolyte is not clear, it has a slightly
white color.

If a heavily discharged battery is recharged immediately after heavy discharge, the sulfation can be reversed.

If these batteries are not recharged, the plates continue to harden and the charge-retention ability becomes limited. The consequence is reduced battery

Safety Precautions|Page 7504 > < Safety Precautions|Page 7502