audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Battery Charge Indicator|Page 7570 > < Battery Charge Indicator|Page 7568
Page 1
background image

Battery: Component Tests and General Diagnostics
Electrolyte Density In All Cells, Checking

Electrolyte Density In All Cells, Checking

Special tools and equipment

-

Hydrometer, commercial type

WARNING:
-

Always pay attention to accident prevention regulations when handling electrolyte. Suitable protective clothing must be worn.

-

When disposing of batteries it is absolutely necessary that disposal Procedures for batteries and sulfuric acid are observed.

NOTE:
-

In conjunction with "voltage under load" test, electrolyte density test gives a good indication of battery condition.

-

Electrolyte temperature must be at least 10 degrees C.

-

The electrolyte density can be checked immediately after battery charging.

Test sequence

-

Remove all battery plugs (battery cell sealing plugs).

-

Immerse hydrometer in one of the cells and draw in electrolyte until float is freely suspended in electrolyte.
-

The greater the specific density of electrolyte drawn in, the higher the float will sit.

-

The specific gravity in kg/cu.dm can be read off from the hydrometer scale.

-

Read off measured value on hydrometer and compare with values listed in table:

Battery Charge Indicator|Page 7570 > < Battery Charge Indicator|Page 7568