Battery: Component Tests and General Diagnostics
Battery, Quick Charging

Battery, Quick Charging

CAUTION!
Risk of injury from battery acid.

‹› Prior to handling or servicing batteries, read, understand and observe the Warnings and Safety Measures for lead-acid batteries for

lead-acid batteries => [ Safety Precautions ] See: Description and Operation/Battery!

‹› Wear protective eyewear and clothing => [ Protect against injury by using protective

eyewear and clothing. ] See: Description and Operation/Battery. 

‹› On non-maintenance-free batteries, the sealing plugs must be installed tightly.

‹› Provide sufficient ventilation.

‹› If the magic eye has no color or is light yellow, the battery may not be tested or charged. Jump starting must not be used! There is a

risk of explosion during testing, charging or jump starting. The battery must be replaced.

‹› DO NOT battery test batteries which are gassing. Otherwise there is a risk of explosion. 

‹› Rapid-charging batteries => [ Battery, Quick Charging ].

‹› Dispose of electrolyte (sulfuric acid/water mixture) properly! Waste electrolyte must only be disposed of in appropriate waste disposal

sites. Refer to local regulations pertaining to electrolyte disposal. 

‹› The following notes and procedures must be followed to ensure correct charging.

Prerequisite

‹› Battery temperature must be at least +10 °C.

Procedure

CAUTION!
Risk of damaging the battery and vehicle electronic components.

‹› DO NOT quick charge AGM batteries!

‹› Batteries in vehicles with Energy Management Control Module (J644) must not be quick charged.

‹› Do not quick charge severely discharged batteries.

‹› Quick charging of batteries should only be performed in exceptional circumstances (e.g. boost starting) as Quick charging may cause

damage.

‹› Battery must not be connected to vehicle electrical system when performing Quick charging. Disconnect the positive and negative

cables from battery terminals.

‹› Do not exceed maximum charging voltage of 14.8 Volts.

‹› If battery is replaced, follow disposal regulations => [ Personal injury and environmental risk. ] See: Description and Operation/Battery. 