audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Battery, Charging With Midtronics Diagnostic Conductance Charging Station INC-940|Page 7588 > < Battery, Charging With Midtronics Diagnostic Conductance Charging Station INC-940|Page 7586
Page 1
background image

Battery: Component Tests and General Diagnostics
Battery, Support Mode With Midtronics Battery Maintainer PSC-550 or Midtronics Battery
Maintainer CXC-2115

Battery, Support Mode with Midtronics Battery Maintainer PSC-550 or Midtronics Battery Maintainer CXC-2115

During electrical troubleshooting or otherwise working on the electrical system where consumers are temporarily switched on, and for working with
any of the VAS 505X class testers in operating mode "Guided Fault Finding " and during software flashing, battery voltage must be must maintained.
Use Midtronics Battery Maintainer (PSC-550) to prevent excessive battery discharge during servicing as described above.

Where it is necessary to maintain battery charge in showroom vehicles for demonstration of electrical features, use Midtronics Battery Maintainer
(CXC-2115).

Special tools, testers and auxiliary items required

‹› Midtronics Battery Maintainer (PSC 550) or 

‹› Midtronics Battery Maintainer (CXC-2115) (VAS charger illustrated here for reference only)

Procedure

CAUTION!
‹› Switch off all electrical consumers. 

‹› Switch ignition off and remove ignition key. 

‹› Depending on use for temporary power supply or voltage maintainer for showroom use, refer to Midtronics Battery Maintainer (PSC

550) or Midtronics Battery Maintainer (CXC-2115 ) Instruction Manuals as necessary.

-

Perform any model-specific preparations necessary to gain access to battery terminals or battery jump-start terminals. 

-

Connect battery maintainer cable clamps to battery terminals or battery jump-start terminals as applicable=> PSC 550 or CXC-2115 Instruction
Manual. Tester leads must be securely fastened and make proper contact with battery posts or jumper terminals.

-

Plug battery maintainer into 120V AC supply to initiate charging => PSC 550 or CXC-2115 Instruction Manual.

Battery, Charging With Midtronics Diagnostic Conductance Charging Station INC-940|Page 7588 > < Battery, Charging With Midtronics Diagnostic Conductance Charging Station INC-940|Page 7586