audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Odometer|Service and Repair|Page 18617 > < Malfunction Indicator Lamp|Testing and Inspection
Page 1
background image

Odometer: Service and Repair

Adaptation (Scan Tool Function 10)

Function 10 is used to initiate and store the following changes:

-

Adaptation of fuel gauge display

-

Correction of the fuel consumption display

-

Coding of language versions for Auto Check system

-

Adaptation of the Service Reminder Indicator (SRI)

-

Setting the odometer after instrument cluster replacement.

Individual functions are called up by entering the appropriate adaptation channel number (See adaptation table).

Adaptation table

Adaptation channel

Adaptation function

01

Adaptation of fuel gauge display

02

Resetting SRI after service

03

Adaptation of fuel consumption display

04

Language versions of the multi-function display

05

SRI - service interval for oil change (distance in km)

06

SRI - service interval 1 (IN1) distance in km

07

SRI - service interval 1 (IN1) time in days

08

SRI - service interval 2 (IN2) time in days

09

Adapting odometer reading

Initiating "Adaptation" function 10

Indicated on display

Rapid data transfer

HELP

Select function XX

-

Press buttons -1- and -0- to select "Adaptation" function 10.

Read Measuring Value Block

Q

10 - Adaptation

Indicated on display

-

Press -Q- button to confirm input.

Indicated on display

Adaptation

Q

Insert channel number XX

-

Insert desired adaptation channel (See Adaptation table).

-

Press -Q- button to confirm input.

NOTE:  After changing an adaptation value or after an adaptation in a specific channel has been completed, Adaptation" function 10 must be selected
again in order to select another adaptation channel.

Adapting odometer display (km/mi)

This function is used to adapt the odometer reading (in km or miles) after replacing the instrument cluster.

NOTE:

-

The adaptation function can only be carried out on an instrument cluster with an odometer reading of not more than 100 kilometers (62 miles).

-

The adaptation function can only be carried out once for each instrument cluster.

-

Only a larger adaptation value can be entered, not a lower one.

-

If an incorrect value is entered and confirmed, no correction is possible. If this is the case, the instrument cluster must be replaced with a new one.

-

In countries where speedometers are calibrated in miles, adjustments must still be made in kilometers. Therefore convert miles to kilometers (miles
x 7.609 = kilometers
) to get the required adaptation value.

Odometer|Service and Repair|Page 18617 > < Malfunction Indicator Lamp|Testing and Inspection