audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Barometric Pressure Sensor|Specifications|Page 7288 > < LED Test Light|Page 7284
Page 1
background image

Barometric Pressure Sensor: Specifications
Sensor Voltage / Resistance

Sensor Voltage / Resistance 

Voltage

4.5 to 5.5 V 

Note: Between connector terminals 1+3 and 2+3

 

   

  

 

Resistance Maximum 1.5 ohms 

Note:  Between connector terminal 1 to ECM/test box socket

 

61. Between connector terminal 2 to ECM/test box socket

 

62. Between connector terminal 3 to ECM/test box socket 67.

 

   

  

 

Resistance Infinite ohms 

Note:  Connector terminal 2 to ECM/test box socket 61.    

 

          Connector terminal 3 to ECM/test box socket 61. 

 

           Connector terminal 3 to ECM/test box socket 62.

 

   

  

 