A4 Quattro Sedan L4-1.8L Turbo (AWM) (2001)
^
Disconnect wiring connectors as follows:
1 - on ACF valve (in addition, remove ACF valve from air filter housing)
2 - on mass air flow sensor
3 - on Wastegate Bypass Regulator valve -N75-
^
Disconnect hose connections, move wiring aside and remove air filter housing -arrows-.
^
Loosen bolted connection of front exhaust pipe/catalytic converter accessible from above.
^
Undo bolts -arrows- of exhaust turbocharger/catalytic converter.
^
Remove catalytic converter upward.
Installing
Installation is carried out in the reverse order of removal.
Note: Always replace seals, gaskets and self-locking nuts.
^
Grease threads of oxygen sensors with high temperature lubricant G 052 112 A3. Apply lubricant only to threads of sensors; the lubricant must not
get into the slots on the sensor body.
^
Align exhaust system stress-free.