Disconnect wiring connectors as follows:
1 - on ACF valve (in addition, remove ACF valve from air filter housing)
2 - on mass air flow sensor
3 - on Wastegate Bypass Regulator valve -N75-

^

Disconnect hose connections, move wiring aside and remove air filter housing -arrows-.

^

Loosen bolted connection of front exhaust pipe/catalytic converter accessible from above.

^

Undo bolts -arrows- of exhaust turbocharger/catalytic converter.

^

Remove catalytic converter upward.

Installing 
Installation is carried out in the reverse order of removal.

Note:  Always replace seals, gaskets and self-locking nuts.

^

Grease threads of oxygen sensors with high temperature lubricant G 052 112 A3. Apply lubricant only to threads of sensors; the lubricant must not
get into the slots on the sensor body.

^

Align exhaust system stress-free.