background image

11

-

Bleed line
-

To EVAP canister

 
Fig. 1 Bleed valve removing, installing, checking Requirement

-

Fuel tank removed.
-

To remove, unclip valve from side of filler-neck.

-

Close off filler-neck by hand -3-.

-

Blow into filler-neck -1-

-

Button -2- pressed in direction of arrow: Flow

-

Button -2- in OFF direction: NO Flow.

 
Fig. 2 Ground connection, installed position

-

Route the Ground connection -Arrow-, as shown in image.

-

Ensure Ground connector fits tightly on filler-neck Ground clamp.

-

Before threading in screw -1-, ensure tight fit of screw eye -2- on fuel filler-neck protection plate Ground -3-.

CAUTION!  After installation, check for continuity between Ground clamp on filler neck and chassis Ground.
-

Specification: approximately 0 ohms.