A4 Quattro Sedan L4-1.8L Turbo (AWM) (2001)
-
Unscrew union nut with 3217 wrench.
-
Remove cover flange and sealing ring from fuel tank opening.
-
Disconnect sender for fuel gauge -G harness connector on inside of cover flange.
-
Disconnect return line on inside of cover flange by pressing unlatch buttons.
-
Insert 3307 fuel pump wrench through fuel tank opening and place on inner section of surge housing.
-
Using wrench 3307, turn surge housing inner section approx. 15° to the left up to the stop and take fuel pump out complete with inner section of
housing.
NOTE: If the supply unit is replaced, empty the old supply unit of any remaining fuel before properly disposing of it.
Cover flange and surge housing inner section, pre-assembling
If cover flange and supply unit were separated
-
Pre-assemble parts.