A4 Quattro Sedan L4-1.8L Turbo (AWM) (2001)
Battery: Testing and Inspection
Specific Gravity, Checking
Specific Gravity, Checking
Special tools, test equipment and auxiliary items
-
Commercially available hydrometer
-
Shop towel
CAUTION!
-
When working with battery acid, make sure to follow all "Warnings and safety precautions for lead-acid batteries. " Wear suitable
protective clothing and eye protection.
-
When disposing of batteries, always comply with applicable Federal, State and local laws regarding the disposal of batteries and sulfuric
acid.
NOTE:
-
In order to better determine the overall condition of a battery, always perform a specific gravity test in conjunction with the load test.
-
The temperature of the electrolyte must be at least 10 °C (50 °F).
The specific gravity can be tested immediately after charging the battery.
Use the following procedure to test the specific gravity in all of the battery cells:
-
Switch ignition off.
-
Remove all cell caps.