After-Run Coolant Pump: Service and Repair
After-Run Coolant Pump

After-Run Coolant Pump

Special tools, testers and auxiliary items required

‹› Hose Clamps up to 25 mm Diameter (3094)

‹› Hose Clamp Pliers (V.A.G 1921)

Removing

-

Loosen hose clamps - arrows - and remove the air guide hose.

‹› Ignore - 1 -.

‹› Lay a cloth below the coolant pipe to catch escaping coolant.

-

Disconnect and remove the coolant hoses - arrows - with Hose Clamps up to 25 mm Diameter (3094).

-

Disconnect electrical connector - 2 -.

-

Remove bolt - 1 - and After-Run Coolant Pump (V51).

Installing