A4 Quattro Sedan L4-2.0L Turbo (CAEB) (2009)
After-Run Coolant Pump: Service and Repair
After-Run Coolant Pump
After-Run Coolant Pump
Special tools, testers and auxiliary items required
‹› Hose Clamps up to 25 mm Diameter (3094)
‹› Hose Clamp Pliers (V.A.G 1921)
Removing
-
Loosen hose clamps - arrows - and remove the air guide hose.
‹› Ignore - 1 -.
‹› Lay a cloth below the coolant pipe to catch escaping coolant.
-
Disconnect and remove the coolant hoses - arrows - with Hose Clamps up to 25 mm Diameter (3094).
-
Disconnect electrical connector - 2 -.
-
Remove bolt - 1 - and After-Run Coolant Pump (V51).
Installing