audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Right Retaining Plate With Right Footwell and Center Vent Motor|Page 8879 > < Right Retaining Plate With Right Footwell and Center Vent Motor
Page 2
background image

-

Disconnect the connector - A - and - B -. 

-

Disconnect the connector from the Evaporator Vent Temperature Sensor (G263). Refer to=> [ Evaporator Vent Temperature Sensor ] See:
Evaporator Temperature Sensor / Switch/Service and Repair. 

-

Loosen the wiring harness - D - from the mounting points on the mounting plate - J -.

-

Carefully loosen the different connecting rods (from -  - to - H -) from each door.

‹› The connecting rods (from - E - through - H -) are clipped on to the levers; unclip them carefully so that the lever does not get damaged.

‹› Depending on the production date, there are different versions of the levers and connections on the A/C unit. Refer to => [ Air Conditioner Levers

] See: Description and Operation/A/C System Control

-

Remove the screws - C -.

-

Remove the mounting plate - J - (together with the control motors, the lever, the cam plate and the connector rods) from the A/C.

Installing

Installation is carried out in the reverse order, when doing this note the following.

-

Apply a small quantity of grease (G 000 150) to the cam plate guides as well as to the pins at the door levers.

-

Make sure the levers, cam plates and connector rod mounting plates -  J - are assembled correctly. Refer to=> [ Right Footwell Door Motor and
Center Vent Motor ] See: Overhaul/Right Footwell Door Motor and Center Vent Motor. 

-

When installing the mounting plate - J - pay attention to the lever pin - K - and the cam plate guide - L -. 

‹› Make sure the curved washer stop - M - is inserted between both stops on the A/C - N - and - O - (the cam plate must be able to move across the

range marked with the arrow).

-

Install the screws - C -.

-

Connect the connector - A - and - B - according to the markings.

-

Mount the wiring harness - D - into the mounting points on the mounting plate - J -.

Right Retaining Plate With Right Footwell and Center Vent Motor|Page 8879 > < Right Retaining Plate With Right Footwell and Center Vent Motor