audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Housing Assembly HVAC|Overhaul > < Evaporator with A/C Unit Installed|Page 9457
Page 11
background image

‹› When bleeding coolant circuit, take special care to ensure complete bleeding of heat exchangers. If there are still air bubbles in the heater core, it

may cause the customer to complain of insufficient heating performance in winter or different air temperature from vents at same setting in
regulated mode. Refer to=> [ Compressor Pulley ] See: Compressor HVAC/Service and Repair 

‹› Depending on vehicle equipment and on engine, heat insulation has been applied to coolant hoses, these must not be damaged and must be

reapplied after installing.

-

Secure the wiring harness once again on the provided places and reinstall the different air guides in reverse order.

-

Install the instrument panel, the center console, and glove box, etc..

‹› When installing the instrument panel, make sure that the "defrost " intermediate piece its properly on A/C unit and the defrost vent does not pinch

the intermediate piece. Refer to=> [ Air Routing and Distribution in Passenger Compartment ] See: Overhaul/Air Routing and Distribution in
Passenger Compartment.

-

Install the remaining removed parts in the opposite order.

-

Reconnect the Battery (A) ground connection; when doing this, pay attention to the notes regarding reconnecting the battery.

-

Evacuate and fill the refrigerant circuit. Refer to A/C System with Refrigerant R134a.

-

Perform a basic setting and the output Diagnostic Test Mode (DTM) on the A/C system. Refer to Vehicle Diagnosis, Testing and Information
System VAS 5051 in "Guided Fault Finding" function.

‹› On this vehicle, the control motors are equipped with electronics, during the first basic setting, a new control motor learns its position on the air

conditioner and can then be controlled by the A/C Control Head Climatronic Control Module (J255) currently all control motors are identical.
Refer to Vehicle Diagnosis, Testing and Information System VAS 5051 in "Guided Fault Finding" function.

‹› During the basic adjustment, the control motors are assigned and adapted corresponding to the switching sequence of the wiring. If this sequence

does not conform the specification, the control motors will adapt incorrectly and the door control will be wrong. Refer to => [ Climatronic Control
Module ] See: Description and Operation/A/C System Control. 

-

Check the A/C control head Climatronic Control Module (J255) DTC memory and erase any displayed malfunction if necessary. Refer to Vehicle
Diagnosis, Testing and Information System VAS 5051 in "Guided Fault Finding" function.

-

Operate the A/C system after filling the refrigerant circuit. Refer to => [ Operating A/C System after Filling Refrigerant Circuit ] See: Description
and Operation/A/C Refrigerant System.

‹› Note the information regarding operating the A/C system after filling.

Housing Assembly HVAC|Overhaul > < Evaporator with A/C Unit Installed|Page 9457