audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Disconnecting and Connecting Refrigerant Lines from Compressor, 4 Cylinder Engine|Page 1776 > < Disconnecting and Connecting Refrigerant Lines from Compressor, 4 Cylinder Engine|Page 1774
Page 3
background image

-

Check the connections in the expansion valve - B - and on the refrigerant line - D - for damage.

-

Replace the quick acting coupling connectors on the refrigerant line with inner heat exchanger. Refer to=> [ Disconnecting and Connecting
Refrigerant Lines, Quick-Release Couplings ] 

-

Replace the O-ring seals - A - and - C - version.

‹› Note the installation instructions for O-ring seals. Refer to => [ Refrigerant Circuit O-Ring Seals ] See: Heating and Air Conditioning/Description

and Operation/Refrigerant Circuit.

-

Coat O-ring seals lightly with refrigerant oil before installing. Refer to=> [ Refrigerant Circuit O-Ring Seals ] See: Heating and Air
Conditioning/Description and Operation/Refrigerant Circuit.

-

Make sure the O-ring seals fit properly in the refrigerant line connection grooves and on the refrigerant line - D -.

-

Tighten the bolts - E - for the refrigerant line -  D - with inner heat exchanger.

‹› Tightening specification for the bolts - E -: 10 Nm. 

-

Tighten the nut - C - for the refrigerant line -  B -.

Disconnecting and Connecting Refrigerant Lines from Compressor, 4 Cylinder Engine|Page 1776 > < Disconnecting and Connecting Refrigerant Lines from Compressor, 4 Cylinder Engine|Page 1774