A4 Quattro Sedan L4-2.0L Turbo (CAEB) (2009)
-
Check the connections in the expansion valve - B - and on the refrigerant line - D - for damage.
-
Replace the quick acting coupling connectors on the refrigerant line with inner heat exchanger. Refer to=> [ Disconnecting and Connecting
Refrigerant Lines, Quick-Release Couplings ]
-
Replace the O-ring seals - A - and - C - version.
‹› Note the installation instructions for O-ring seals. Refer to => [ Refrigerant Circuit O-Ring Seals ] See: Heating and Air Conditioning/Description
and Operation/Refrigerant Circuit.
-
Coat O-ring seals lightly with refrigerant oil before installing. Refer to=> [ Refrigerant Circuit O-Ring Seals ] See: Heating and Air
Conditioning/Description and Operation/Refrigerant Circuit.
-
Make sure the O-ring seals fit properly in the refrigerant line connection grooves and on the refrigerant line - D -.
-
Tighten the bolts - E - for the refrigerant line - D - with inner heat exchanger.
‹› Tightening specification for the bolts - E -: 10 Nm.
-
Tighten the nut - C - for the refrigerant line - B -.