A4 Quattro Sedan L4-2.0L Turbo (CAEB) (2009)
-
Position the hydraulic oil cooler - 1 - on the brackets - 2 - and then engage it into the brackets - 3 -.
Lines to the hydraulic oil cooler, refer to => [ Hoses to Reservoir, Hydraulic Oil Cooler and Return Line, Installation
Locations ] See: Hoses to Reservoir, Hydraulic Oil Cooler and Return Line, Installation Locations.
Pressurized line to crossbrace
-
Install the pressure line on the crossbrace using the nut - 3 - and rubber bushing - 4 -.
-
Note the line installation location when bolting the line connection. The markings - 1 - and - 2 - must be opposite each other.
Pressurized line to the engine mount